CZL 601 Load cell

CZL 601 Load cell
CZL 601 Load cell

CZL 601 Load cell Specification

  • Application
  • Hospitals/laboratories
  • Color
  • White
  • Usage
  • Tester
  • Voltage
  • 220/240 Volt (v)
  • Dimension (L*W*H)
  • 130 x 30 x 22 Millimeter (mm)
  • Material
  • Mild Steel
  • Product Type
  • Weighing Scale
  • Weight
  • 200 Grams (g)
  • Power
  • 20 Ampere (amp)
  • Output
  • Digital Sensor
  • Type
  • Scale
 

CZL 601 Load cell Trade Information

  • Minimum Order Quantity
  • 1 Number
  • Supply Ability
  • 1000 Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About CZL 601 Load cell

Performance Specification

Standard Capacities

3, 6, 10, 15, 20, 30, 40, 60 - Kgf

Excitation Voltage

10 VDC- Maximum 15 VDC

Nominal Output

2.0 mV/ V

Non - Linearity

< ±0.025% FSO

Hysteresis

< ±0.02% FSO

Non-Repeatability

< ±0.01% FSO

Creep (30 minutes)

< ±0.03% FSO

Zero Balance

±1.0% FSO

Input Resistance

400 ± 15 Ohms

Output Resistance

350 ± 5 Ohms

Insulation Resistance (50 VDC)

> 1000 Mega Ohms

Cable Length (4 Core Screened)

500 mm. Minimum

Safe Overload of Rated Capacity

150%

Ultimate Overload of Rated Capacity

200%

Temp. Compensated Range

0-60 0C

Temperature Effect on Output

< 0.0015% FSO/ 0C

Temperature Effect on Zero

< 0.0020% FSO/ 0C

Platter Size

300mm X 300mm

Eccentric Load Effect

< 0.02% of FSO at 1/3 rated load placed within the specified sized platter

Deflection

< 0.5 mm at FSO

Tightening Torque

1.5 m.kg.

Finish & Construction

Aluminium Alloy

Environmental Protection Class

IP65


Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Load Cell Category

High-Precision Load Cells

High-Precision Load Cells

Price 300 INR / Piece

Minimum Order Quantity : 10 Pieces



Back to top